STEREO RECEIVER
RX-797
SERVICE MANUAL
IMPORTANT NOTICE
This manual has been provided for the use of authorized YAMAHA Retailers and their service personnel.
It has been assumed that basic service procedures inherent to the industry, and more specifically YAMAHA Products, are already
known and understood by the users, and have therefore not been restated.
WARNING:
Failure to follow appropriate service and safety procedures when servicing this product may result in personal
injury, destruction of expensive components, and failure of the product to perform as specified. For these reasons,
we advise all YAMAHA product owners that any service required should be performed by an authorized YAMAHA
Retailer or the appointed service representative.
recognition of any applicable technical capabilities, or establish a principle-agent relationship of any form.
IMPORTANT:
The presentation or sale of this manual to any individual or firm does not constitute authorization, certification or
The data provided is believed to be accurate and applicable to the unit(s) indicated on the cover. The research, engineering, and service
departments of YAMAHA are continually striving to improve YAMAHA products. Modifications are, therefore, inevitable and
specifications are subject to change without notice or obligation to retrofit. Should any discrepancy appear to exist, please contact the
distributor's Service Division.
WARNING:
Static discharges can destroy expensive components. Discharge any static electricity your body may have
accumulated by grounding yourself to the ground buss in the unit (heavy gauge black wires connect to this buss).
IMPORTANT:
Turn the unit OFF during disassembly and part replacement. Recheck all work before you apply power to the unit.
s
CONTENTS
TO SERVICE PERSONNEL . . . . . . . . . . . . . . . . . . . . 2
IMPEDANCE SELECTOR . . . . . . . . . . . . . . . . . . . . . . 3
FRONT PANELS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
REAR PANELS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–5
REMOTE CONTROL PANELS . . . . . . . . . . . . . . . . . . 5
SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . 6–7
INTERNAL VIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
DISASSEMBLY PROCEDURES . . . . . . . . . . . . . . . . . 8
SELF DIAGNOSIS FUNCTION . . . . . . . . . . . . . . . 9–15
AMP ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . 16
IC DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17–18
DISPLAY DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
PRINTED CIRCUIT BOARD . . . . . . . . . . . . . . . . 20–28
PIN CONNECTION DIAGRAM . . . . . . . . . . . . . . . . . 29
BLOCK DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
SCHEMATIC DIAGRAM . . . . . . . . . . . . . . . . . . . 31–34
PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35–43
REMOTE CONTROL RAX100/RAX101 . . . . . . . . . . 44
REMOTE CONTROL RAX17 . . . . . . . . . . . . . . . . . . 45
REMOTE CONTROL RAX18 . . . . . . . . . . . . . . . . . . 46
RX-797
DPX-1200
100979
© 2005 YAMAHA CORPORATION. All rights reseved.
This manual is copyrighted by YAMAHA and may not be copied or
redistributed either in print or electronically without permission.
’05.10
RX-797
s
TO SERVICE PERSONNEL
1. Critical Components Information
Components having special characteristics are marked
Z
and must be replaced with parts having specifications equal
to those originally installed.
2. Leakage Current Measurement (For 120V Models Only)
When service has been completed, it is imperative to verify
that all exposed conductive surfaces are properly insulated
from supply circuits.
q
WALL
OUTLET
EQUIPMENT
UNDER TEST
AC LEAKAGE
TESTER OR
EQUIVALENT
INSULATING
TABLE
q
q
Meter impedance should be equivalent to 1500 ohms shunted
by 0.15µF.
Leakage current must not exceed 0.5mA.
Be sure to test for leakage with the AC plug in both
polarities.
“CAUTION”
“F251, F252 : FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 8A, 125V FUSE.”
A
V
CAUTION
F251, F252 : REPLACE WITH SAME TYPE 8A, 125V FUSE.
ATTENTION
F251, F252 : UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE DE 8A, 125V.
WARNING: CHEMICAL CONTENT NOTICE!
The solder used in the production of this product contains LEAD. In addition, other electrical/electronic and/or
plastic (where applicable) components may also contain traces of chemicals found by the California Health and
Welfare Agency (and possibly other entities) to cause cancer and/or birth defects or other reproductive harm.
DO NOT PLACE SOLDER, ELECTRICAL/ELECTRONIC OR PLASTIC COMPONENTS IN YOUR MOUTH FOR
ANY REASON WHATSOEVER!
Avoid prolonged, unprotected contact between solder and your skin! When soldering, do not inhale solder fumes
or expose eyes to solder/flux vapor!
If you come in contact with solder or components located inside the enclosure of this product, wash your hands
before handling food.
About Lead Free Solder
The P.C.B.s installed in this unit are soldered using the following solder.
SIDE A
FUNCTION P.C.B.
OPERATION P.C.B.
MAIN P.C.B.
XM P.C.B.
Lead Free Solder
SIDE B
Lead Free Solder
Lead Free Solder
Lead Free Solder
Lead Free Solder
Side A
SMT
REFLOW
Process
RX-797
Solder Dip
Side B
MI
Caution:
FLOW
Process
Among some types of lead free solder currently available, it
is recommended to use one of the following types for the
repair work.
• Sn + Ag + Cu (tin + silver + copper)
• Sn + Cu (tin + copper)
• Sn + Zn + Bi (tin + zinc + bismuth)
1. As the melting point temperature of the lead free solder is about 30°C to 40°C (50°F to 70°F) higher than that of the lead
solder, be sure to use a soldering iron suitable to each solder.
2. If lead solder must be used, be sure to remove lead free solder from each terminal section of the parts to be replaced and from
the area around it completely before soldering, or make sure that the lead free solder and lead solder melt together fully.
2
RX-797
s
IMPEDANCE SELECTOR
WARNING:
Do not change the setting of the IMPEDANCE SELECTOR switch
when the unit power is switched on, as doing so may damage
the unit.
IMPEDANCE SELECTOR
s
FRONT PANELS
w
U, C models
w
R, A, G, E, L models
RX-797
DPX-1200
3
RX-797
s
REAR PANELS
w
U, C models
w
R model
w
A model
RX-797
4
RX-797
w
G, E models
w
L model
s
REMOTE CONTROL PANELS
w
RAX100
(U, C models)
w
RAX101
(R, A, G, E, L models)
w
RAX17
(U, C models)
w
RAX18
(R, A, G, E, L models)
RX-797
DPX-1200
5
Zgłoś jeśli naruszono regulamin