Loader interface "General" (V03.03)
1 Loader interface "General" (V03.03)
1.1
Plug connection between the loader and machine
"Hardware interface"
(option)
For the interface, two 24-pin plug connections with screw connection and cross-shackle are used.
CHIRON
Pins
Signals
from machine
to loader
Loader
X 104
Control
cabinet
X 105
Signals
from loader
to machine
Control
cabinet
Sockets
1.1.1
Supply of control signals
Control signal supply with +24V DC (P switching)
All signals must be conducted electrically isolated.
The evaluation components are supplied with +24V DC (P switching).
The reference potential of the evaluation components is 0 V.
1.1.2
Machine operation "without" loader
If the machine is run
without
a loader, a blind plug (X105.1) is required on the machine for bypassing the
EMERGENCY STOP circuit so that the machine control can be connected.
19.03.2007 09:28:00 / Hirt Rolf
SPB - laderschnittstelle-allgemein-v03-03-mu-en.doc
1
Loader interface "General" (V03.03)
1.1.3
Schematic diagram of loader with "hardware interface"
( * option)
19.03.2007 09:28:00 / Hirt Rolf
SPB - laderschnittstelle-allgemein-v03-03-mu-en.doc
2
Loader interface "General" (V03.03)
1.2
Plug connection between loader and machine
"Profibus interface"
For the interface (emergency stop / safety fence) two
24-pin
plug connections are used with screw
connection and cross-shackle.
The
advantage
of Profibus compared to the "hardware wiring" is that one needs
no additional wiring,
if
one or more signals are added.
1.2.1
Profibus interface
Depending on the machine type, the "Profibus" option may be required.
Furthermore, the corresponding "DP/DP
coupler"
must be present on the machine which allows
communication between the machine and the loader.
CHIRON
X 104
Control cabinet
Pins
Signals
from the machine
to the
loader
(EMERGENCY STOP)
Loader
Sockets
Signals
from the loader
to the
machine
(EMERGENCY STOP / safety fence)
Control
X 105
CNC
Master
Profibus
Slave
Coupler
Slave
(32 x outputs / 32 x inputs)
System
Master
1.2.2
Profibus
The
standard
Profibus interface is designed for
32 outputs
and
32 inputs.
(Profibus can be extended to a maximum of 256 inputs and 256 outputs).
1.2.3
Machine operation "without" loader
If the machine is run
without
a loader, a blind plug (X105.1) is required on the machine for bypassing the
EMERGENCY STOP circuit so that the machine control can be connected.
19.03.2007 09:28:00 / Hirt Rolf
SPB - laderschnittstelle-allgemein-v03-03-mu-en.doc
3
Loader interface "General" (V03.03)
1.2.4
Schematic diagram of loader with "Profibus interface"
19.03.2007 09:28:00 / Hirt Rolf
SPB - laderschnittstelle-allgemein-v03-03-mu-en.doc
4
Loader interface "General" (V03.03)
1.2.5
Information regarding the DP/DP coupler
(6ES7 158-0AD01 0XA0)
During project planning, it must be made sure that the input/output areas of both networks are
adapted to each other.
The DP/DP coupler project planning is done using a corresponding device master file (GSD).
Further details about the DP/DP coupler can be found in the manufacturer documentation.
DP1 address
Machine
Example:
Machine =
16
DP2 address
Loader
Example:
Loader =
10
Project planning
CHIRON
Output range
PROFIBUS DP
Network 1
EB+0
EB+1
Loader
Input range
PROFIBUS DP
Network 2
AB+0
AB+1
Input range
PROFIBUS DP
Network 1
AB+0
AB+1
Output range
PROFIBUS DP
Network 2
EB+0
EB+1
19.03.2007 09:28:00 / Hirt Rolf
SPB - laderschnittstelle-allgemein-v03-03-mu-en.doc
5