Loader interface "General" (V03.03)
1 Loader interface "General" (V03.03)
1.1
Plug connection between the loader and machine
"Hardware interface"
(option)
⇒
For the interface, two 24-pin plug connections with screw connection and cross-shackle are used.
CHIRON
Pins
Signals
from machine
to loader
Loader
X 104
Control
cabinet
X 105
Signals
from loader
to machine
Control
cabinet
Sockets
1.1.1
Supply of control signals
⇒
Control signal supply with +24V DC (P switching)
⇒
All signals must be conducted electrically isolated.
⇒
The evaluation components are supplied with +24V DC (P switching).
The reference potential of the evaluation components is 0 V.
1.1.2
Machine operation "without" loader
⇒
If the machine is run
without
a loader, a blind plug (X105.1) is required on the machine for bypassing the
EMERGENCY STOP circuit so that the machine control can be connected.
19.03.2007 09:28:00 / Hirt Rolf
SPB - laderschnittstelle-allgemein-v03-03-mu-en.doc
1
Loader interface "General" (V03.03)
1.1.3
Schematic diagram of loader with "hardware interface"
( * option)
19.03.2007 09:28:00 / Hirt Rolf
SPB - laderschnittstelle-allgemein-v03-03-mu-en.doc
2
Loader interface "General" (V03.03)
1.2
Plug connection between loader and machine
"Profibus interface"
⇒
For the interface (emergency stop / safety fence) two
24-pin
plug connections are used with screw
connection and cross-shackle.
⇒
The
advantage
of Profibus compared to the "hardware wiring" is that one needs
no additional wiring,
if
one or more signals are added.
1.2.1
Profibus interface
⇒
Depending on the machine type, the "Profibus" option may be required.
⇒
Furthermore, the corresponding "DP/DP
coupler"
must be present on the machine which allows
communication between the machine and the loader.
CHIRON
X 104
Control cabinet
Pins
Signals
from the machine
to the
loader
(EMERGENCY STOP)
Loader
Sockets
Signals
from the loader
to the
machine
(EMERGENCY STOP / safety fence)
Control
X 105
CNC
Master
Profibus
Slave
Coupler
Slave
(32 x outputs / 32 x inputs)
System
Master
1.2.2
Profibus
⇒
The
standard
Profibus interface is designed for
32 outputs
and
32 inputs.
(Profibus can be extended to a maximum of 256 inputs and 256 outputs).
1.2.3
Machine operation "without" loader
⇒
If the machine is run
without
a loader, a blind plug (X105.1) is required on the machine for bypassing the
EMERGENCY STOP circuit so that the machine control can be connected.
19.03.2007 09:28:00 / Hirt Rolf
SPB - laderschnittstelle-allgemein-v03-03-mu-en.doc
3
Loader interface "General" (V03.03)
1.2.4
Schematic diagram of loader with "Profibus interface"
19.03.2007 09:28:00 / Hirt Rolf
SPB - laderschnittstelle-allgemein-v03-03-mu-en.doc
4
Loader interface "General" (V03.03)
1.2.5
Information regarding the DP/DP coupler
(6ES7 158-0AD01 0XA0)
⇒
During project planning, it must be made sure that the input/output areas of both networks are
adapted to each other.
⇒
The DP/DP coupler project planning is done using a corresponding device master file (GSD).
⇒
Further details about the DP/DP coupler can be found in the manufacturer documentation.
DP1 address
Machine
Example:
Machine =
16
DP2 address
Loader
Example:
Loader =
10
Project planning
CHIRON
Output range
PROFIBUS DP
Network 1
EB+0
EB+1
Loader
Input range
PROFIBUS DP
Network 2
AB+0
AB+1
Input range
PROFIBUS DP
Network 1
AB+0
AB+1
Output range
PROFIBUS DP
Network 2
EB+0
EB+1
19.03.2007 09:28:00 / Hirt Rolf