CRIMPED TERMINATIONS
PARALLEL SPLICES
PARALLEL SPLICES
Parallel splices are used to dress and
terminate multiple conductors, of the same or
different gauges, in a parallel configuration.
See Section 2.01 “Crimped Terminations –
General Requirements” for common accept /
reject criteria.
PREFERRED
SINGLE CRIMP INSULATED
The contact has been deformed only by tool
indenters. Indents are symmetrical and centered
on the crimp barrel. No exposed base metal or
other damage. Wire strand ends are visible.
Proper insulation spacing (C).
NASA-STD-8739.4 [ 19.6.1.c ]
PREFERRED
DUAL CRIMP INSULATED
The contact has been deformed only by tool
indenters. Indents are symmetrical and properly
located. Insulation crimps are properly set to
provide appropriate strain relief. No exposed
base metal. Proper insulation spacing (C).
NASA-STD-8739.4 [ 19.6.1.c ]
PREFERRED
UNINSULATED
The contact has been deformed only by tool
indenters. Indents are symmetrical and centered
on the crimp barrel. No exposed base metal or
other damage. Wire strand ends are visible.
Proper insulation spacing (C).
NASA-STD-8739.4 [ 19.6.1.c ]